Best Practice
Parameters Case 1
Requirements of the customer:
- Material: PP, non-conductive
- Application: FLAIR plasma treatment in a cast film system
- Treatment width/pages to be treated: 2,850 mm / 1-sided
- Production/max. machine speed: 300 m/min / max. 500 m/min
- Height inlet/outlet: 2.210 / 500 mm
- Material thickness: 12 – 250 μm
Supplied Features:
- Generator power: 50 kW
- Electrode type: FLAIR
- Roll surface: stainless steel
- Plasma dose: 58.5 Wmin/m2 at 300 m/min
- Achievable surface tension: 52 mN/m.
Parameters Case 2
Requirements of the customer:
- Material: PP backsheet foil and others other non-conductive foils
- Application: single/double-sided FLAIR treatment in a blown film line
- Treatment width/pages to be treated: 2,200 mm / 1(2)-sided
- Production/max. machine speed: 15 m/min / n.n.
- Material thickness: 360 µm and thinner
Supplied Features:
- Generator power: 2x 10 kW
- Electrode type: FLAIR, segmented, grid 8 mm
- Roll surface and diameter: stainless steel, 200 mm
- Plasma dose: 300 Wmin/m² at 15 m/min
- Achievable surface tension: 72 mN/m on the backsheet film, measured according to ISO 8296 or FINAT FTM 15 Series A or B, max. 60 minutes after treatment under laboratory condition 23/50 according to ISO 291.